Esmil DAF Unit

TYPE OF INDUSTRY – Fish processing
MODEL OF DAF-UNIT – FT-20Z with static mixer
START OF OPERATION – 2019 March

Issue

The customer was looking for the solution to reduce pollutants in wastewater from the fish processing plant, after the FBR advanced oxidation process. Moreover, they were looking for the compact and easy to operate system, with low operating costs.

Solution

Based on initial information and theoretical calculations, Esmil in cooperation with our representative in Canada Archer Separation Inc. offered DAF-unit FT-20Z.

Wastewater Sourceseawater with fish farm byproducts
Operating Time16-20 h/day, 3-4 days/week
Flow Rate20-40 m3/h
Feed TSS Concentration800-1200 ppm
Effluent TSS Concentration80-100 ppm